TI AUTOMOTIVE · PART DECISION PAGE
INA241A-Q1
Precision −5 to 110V common-mode current amplifier with PWM rejection
Measures shunt drops through switching common-mode transitions for motor or power nodes needing PWM rejection and bidirectional sensing. Budget offset and gain error by A1–A5 using the Rev D electrical table rather than applying the headline ±10µV to every gain. The orderable example is limited to a Grade 1 A1 part; the shared A/B material's Grade 0 claim is not assigned to the A series.
5-second verdict
Key specifications
Orderable variants (OPNs)
The GPN is for selection; the full OPN is for ordering. These examples were observed on the verification date, not live stock. Variants may differ in package, temperature, gain/threshold and, for PMICs, NVM/sequencing. Distinguish TA from TJ in the exact datasheet.
| OPN | Package | Temperature | Note |
|---|---|---|---|
| INA241A1QDDFRQ1 | SOT-23-THN (DDF) · 8 pin | -40 to +125°C (TI OPN listing; verify TA/TJ) | Verify exact OPN, temperature definition and revision; not a stock claim. |
Official ordering page: https://www.ti.com/product/INA241A-Q1
Typical applications
FAQ
Can A1 and A5 share a ±10µV, ±0.01% error budget?
No. Rev D specifies maximum offsets of ±20µV for A1 and ±8µV for A5 at 25°C, VS=5V, VCM=48V and both reference inputs at VS/2. Maximum gain error is ±0.01% for A1–A3 and ±0.015% for A4/A5. Gain accuracy requires GND+50mV < VOUT < VS−200mV; add drift for an over-temperature budget.
Why is the orderable example Grade 1 rather than the shared page's Grade 0?
This follows the family-variant scope, not grade inference from temperature. The shared datasheet explicitly lists Grades 1/0 and restricts its +150°C electrical conditions to INA241B3EDRQ1. This page selects only verified INA241A1QDDFRQ1, Grade 1, TA −40 to +125°C. Discussing A1–A5 parameters does not claim orderable coverage of every gain.
Can it measure across −20 to 120V or directly sense a high-voltage traction pack?
No. −20 to 120V is a survival range; operating common mode is −5 to 110V, separate from the 2.7–20V supply range. The device provides no galvanic isolation. Inputs relative to local ground must meet operating limits and cannot be connected directly across a several-hundred-volt traction pack.
How should I verify the INA241A-Q1 orderable?
The page lists 1 OPN examples from official material checked on 2026-11-06. Match package, function options and temperature definitions; obtain live price/stock from TI or authorized distributors.
Sources and verification
Related selection and design checks